A boiler feedwater deaerator strips dissolved oxygen and carbon dioxide out of feedwater before that water reaches a hot boiler tube, and the target it has to hit is specific. The U.S. Department of Energy puts the requirement at 5 parts per billion of dissolved oxygen or lower to prevent corrosion in most high-pressure boilers, meaning those above 200 psi. Low-pressure boilers can tolerate up to about 43 ppb, but DOE still recommends holding the same 5 ppb limit, because the added equipment life costs almost nothing to buy. Inside an industrial steam boiler system, the deaerator also preheats returned condensate and makeup water, and it gives the feed pump the storage volume and suction head it needs. The unit therefore gets specified alongside the boiler, not after it.
The scope here is narrow: what the deaerator removes, pressurized deaerator versus atmospheric feedwater tank, how tray and spray designs differ in service, which inputs drive sizing, and how to verify the unit is working. Vent piping layout, feed pump internals, the upstream water treatment train and clause-level code interpretation are out of scope.
What a Boiler Feedwater Deaerator Removes
A deaerator takes out what is in solution. Oxygen and carbon dioxide arrive dissolved in makeup water and in air that has worked its way into the condensate system, and a working unit strips the carbon dioxide out essentially completely. Neither gas is touched by filtration or softening.
Oxygen is the gas that ruins tubes. Dissolved oxygen attaches to metal surfaces and forms oxides, and the damage concentrates as pitting, so a boiler can fail at a pinhole long before its average wall thickness looks alarming. Carbon dioxide dissolves into condensate and forms carbonic acid, which attacks return lines from the inside. Where both gases are present, water-treatment and equipment sources put the combined corrosive effect at roughly 40% higher than either gas acting alone.
One boundary is worth knowing before anyone starts troubleshooting: a deaerator removes oxygen dissolved in the entering water, not entrained air. DOE spells this out, and the sources of that free air are mundane — loose pipe connections on the suction side of pumps, and worn or badly set pump packing. Plants lose days chasing a high dissolved oxygen reading through the deaerator internals when air is being pulled in downstream of it.
Deaeration also does nothing about hardness. Softening and any other mineral control still belong upstream of the feedwater tank, and existing steam boiler scale still has to be cleaned out on its own schedule.
How Deaeration Happens Inside the Vessel
Deaeration needs three conditions at once. The water has to reach the saturation temperature for the vessel pressure, it has to be broken into a large surface area, and scrubbing steam has to sweep through it and carry the liberated gases to a vent. Remove any one of the three and the unit becomes an expensive hot water tank.

Water that never reaches saturation temperature never gives up its gas. Oxygen and carbon dioxide grow steadily less soluble as temperature climbs, so the deaerator drives the water to within a few degrees of the saturation temperature of the steam it sits in. Outlet water running well below that point still holds dissolved gas, no matter how healthy the vent looks.
Non-condensable gases have to leave continuously through the vent, or they redissolve as the water cools on its way to the pump. Throttling the vent valve to hold vessel pressure is the frequent operating error here. Pressure control belongs to the steam pressure reducing valve; the vent only clears non-condensables.
Below the deaeration section sits the storage tank, whose steam blanket keeps deaerated water from picking oxygen back up. DOE also credits deaerators with providing the storage capacity and the net positive suction head needed at the boiler feed pump inlet, which ties vessel elevation to pump selection.
Deaerator or Atmospheric Feedwater Tank
Boiler pressure, makeup fraction, and the dissolved oxygen limit decide whether a plant needs a pressurized deaerator or can live with an atmospheric feedwater tank. Tank shape and footprint decide nothing.
An atmospheric feedwater tank relies on preheat alone, and preheat alone leaves residual oxygen an order of magnitude or more above what a pressurized unit delivers. Mechanical deaeration in a pressurized vessel releases 97 to 98% of the oxygen in the incoming water, and those vessels are normally guaranteed to an outlet of 0.005 cc per liter, about 7 ppb. No atmospheric tank can be tuned into that range, so a boiler that has to hold 5 ppb has already made the decision.

Both units occupy the same slot on a boiler equipment list and look alike in a plan view. The difference lies in whether the water is brought to saturation under pressure and scrubbed with steam, or merely warmed.
Four variables settle the question in practice:
- Boiler operating pressure. Above roughly 200 psi, the 5 ppb target applies, and an atmospheric tank cannot reach it.
- Makeup fraction. Heavy makeup brings a dissolved gas load in continuously, which pushes even a low-pressure plant toward a true deaerator.
- Condensate return rate and temperature. Plants returning most of their condensate hot take in far less oxygen and have more room to argue.
- The dissolved oxygen limit the plant is held to. Insurers, warranty terms and the water treatment program often set a number stricter than the boiler’s nameplate would suggest.
Verify with one measurement: dissolved oxygen downstream of the deaerator at operating load, not in the tank and not on a design sheet.
Tray-Type and Spray-Type Deaerators Compared
Achievable ppb settles nothing here, because tray-type and spray-type deaerators are normally sold against the same oxygen guarantee. What separates them is behavior under swinging load, how much internal hardware there is to maintain, and what the vessel costs installed.
A tray-type unit puts a deaeration column above a horizontal storage vessel. Feedwater cascades down through perforated trays while low-pressure steam rises counter to it, and that counterflow sustains contact time across a wide range of flows. The trays are also the part that fails. A slug of cold water or an interrupted steam supply can lift or collapse them, and a collapsed tray shows up immediately as high outlet oxygen.
Spray-type units do the same work in one horizontal vessel, spraying feedwater into saturated steam through a preheat section before scrubbing. Fewer internals mean a simpler vessel and a lower first cost. The nozzles then become the performance-limiting item: a worn aperture, a broken spring or a plugged nozzle degrades deaeration long before anything else looks wrong.

Published turndown ratios, service-life estimates and oxygen guarantees for both designs come out of individual manufacturers’ catalogs, not from an industry-wide test standard, so they do not transfer between suppliers. Ask for the guaranteed turndown and the guaranteed outlet oxygen at your minimum load, with your makeup fraction, in writing. Then put both numbers into the purchase specification, where they can be enforced.
| Decision dimension | Tray-type | Spray-type | How to settle it |
|---|---|---|---|
| Swinging or low-turndown load | Counterflow contact holds up across a wide flow range | Performance is tied to spray quality at the nozzle | Give the supplier your minimum and peak feedwater flow; ask for guaranteed oxygen at the minimum |
| Maintenance exposure | Trays can lift or collapse after cold-water or steam upsets | Nozzles wear, plug and lose spring tension | Ask what has to be pulled to inspect internals, and how often |
| Installed cost and complexity | Column plus storage vessel; more hardware | Single vessel; typically cheaper first cost | Weigh first cost against the cost of an oxygen excursion |
Sizing Inputs That Change the Unit You Buy
Size the deaerator from confirmed peak feedwater demand and the stripping steam available to it, never from boiler horsepower and a catalog table. Six inputs need to be locked down before a quote means anything:
- Peak feedwater flow, including simultaneous cold starts on more than one boiler
- The worst-case makeup-to-condensate ratio, not the average one
- Steam supply pressure at the deaerator connection, and how stable it is
- The dissolved oxygen target the unit must guarantee
- Required storage time at full load
- The design code the vessel must be built and stamped to
Storage volume buys time, not deaeration. Common practice sizes the storage section on the order of several minutes to ten minutes of full-load feedwater, but check that figure against how the plant actually behaves. Sharp load swings and long boiler startups need more ride-through than a steady-load site.
Deaerators fail quietly on steam supply. A sudden increase in free or flash steam can spike vessel pressure, and DOE is explicit that this re-oxygenates the feedwater. A dedicated pressure-regulating valve should therefore hold the deaerator at constant pressure; a shared or undersized reducing station turns the problem into intermittent oxygen excursions nobody can reproduce on demand.
Deaerated water leaves near saturation, which makes available NPSH thin by definition and puts vessel elevation into the sizing conversation. Check the boiler feed pump’s NPSHr curve at the hottest water the deaerator will actually produce, then close the gap by raising the vessel or specifying a pump with a low NPSH requirement. Skip that check and the cavitation gets blamed on the pump.
Confirm the code stamp before the order, not after delivery. Pressurized deaerator vessels in the U.S. market are typically built to ASME Section VIII, Division 1, which covers materials, fabrication, inspection and certification for pressure vessels above 15 psig.
Operating Targets and the First Failures to Check
Four readings, in this order, tell whether the unit is working: dissolved oxygen downstream of it, outlet temperature against saturation at vessel pressure, a steady vent plume, and stable pressure over a shift.

Outlet temperature moves before the oxygen log does, which makes it the fastest check on the list. Typical low-pressure installations run around 5 to 7 psi and 225 to 227°F, and DOE puts the range across all deaerators at 215°F to more than 350°F, depending on the pressure the vessel is held at. What matters is outlet temperature relative to saturation at the actual vessel pressure: a unit sitting several degrees low is not deaerating, whatever its oxygen log says an hour later.
When dissolved oxygen jumps, work the causes in this order:
- Internals. A plugged spray nozzle or a tray lifted out of position is the first item to inspect, particularly after a cold-water slug or a steam interruption.
- Steam supply pressure. Insufficient inlet steam starves the stripping action even when the vessel looks warm. Check the reducing valve’s sizing and the pressure it actually delivers.
- The vent. A blocked or closed-off vent traps non-condensables in the vessel, and the signature is unmistakable: temperature drops while pressure holds.
- Air in-leakage. If the first three check out, look at the pump suction side for loose connections and packing that let free air in. The deaerator was never going to remove it.
No published vent rate is safe to use as a target. The available rules of thumb disagree and do not even share a denominator: some give a share of the steam entering the vessel, others a share of feedwater flow. Take the design vent rate from the manufacturer’s data for the specific unit, and verify it in the field. A steady, visible plume with no periodic burping is what to look for; burping signals steam condensing in the vent line and gases that are not getting out.
A chemical scavenger cleans up what the vessel leaves behind; it does not control deaeration. Mechanical deaeration cannot reach zero oxygen, so the scavenger handles the residual traces, dosed into the storage section where it has the longest contact time before the pump. Scavenger chemistry is constrained at higher boiler pressures, which makes the selection a water treatment decision. Rising scavenger demand at steady load is worth reading as a symptom: inspect the deaerator, not the dosage.
Conclusion
Work a deaerator decision in one order, and most of the argument disappears. Fix the dissolved oxygen target first, because it decides pressurized versus atmospheric before anything else is on the table. Settle the worst-case makeup fraction next, since that sets both the gas load and the stripping steam. Only then compare tray against spray, using minimum load and maintenance access as the deciding dimensions instead of first cost. Elevation, the dedicated pressure-regulating valve and the vessel code come last, but they determine whether the unit holds its number in service.
When we scope a feedwater package, the numbers we ask for first are peak feedwater flow, worst-case makeup fraction, steam pressure at the deaerator connection, the dissolved oxygen target and required storage time. Quotes built on those five inputs are comparable; quotes built on boiler horsepower differ mainly in tank size. The deaerator worth paying for is the one that still holds its outlet oxygen at target through a cold-makeup startup, with a steady vent plume and a feed pump that is not cavitating on saturated water.
Further Reading
- Deaerators in Industrial Steam Systems, Steam Tip Sheet #18 — U.S. Department of Energy. Source of the 5 ppb and 43 ppb oxygen targets used above, and of the distinction between dissolved oxygen and entrained air. Written for industrial steam systems, so its steam-consumption and vent discussion assumes a plant-scale deaerator, not a package hot water unit.
- BPVC Section VIII, Division 1: Rules for Construction of Pressure Vessels — ASME. The construction code most U.S. pressurized deaerator vessels are built and stamped to, covering materials, fabrication, inspection and certification above 15 psig. Use it to check what the supplier’s stamp actually commits them to, not as a design manual.
- Heat Exchange Institute — HEI. The industry body that publishes standards for deaerators and related heat transfer equipment, and the reference point when a supplier’s turndown or oxygen guarantee has to be compared against something other than its own catalog.
FAQ
What dissolved oxygen level should a boiler feedwater deaerator reach?
Do low-pressure boilers need a deaerator?
Does a deaerator remove carbon dioxide?
Can a deaerator replace an oxygen scavenger?
Why did dissolved oxygen suddenly rise after the deaerator?